Auxiliary Panic: Panic keys [4] and [6] (page 25) or the
appropriate button(s) on a remote control (page 20)
have been pressed.
Fire Panic: Panic keys [7] and [9] (page 25) or the
appropriate button(s) on a remote control (page 20)
have been pressed.
Recent Closing: Reports when an alarm is generated
after arming the system within period defined by the
Recent Close Delay (see page 30).
Section [140]
Auto-zone Shutdown: A zone communicates more than
the programmed number of transmissions in a single
armed period (see page 17).
Duress: A Duress access code is keyed in (see
page 14).
Paramedical alarm
Future use
Zone Tamper Report Codes
Section [141] to [144]
A report code can be programmed for each of the 16
available zones. Whenever a tamper or wire fault occurs on
a zone, the Magellan console can send the appropriate
report code to the central station identifying which zone was
tampered.
If Tamper Recognition (see page 24) is disabled, the
console will not report the occurrence of any tampers, wire
faults or tamper restores.
Zone Tamper Restore Report Codes
Sections [145] to [148]
A report code can be programmed for each of the 16
available zones. Whenever a tampered zone is restored, the
Magellan console can send the appropriate report code to
the central station identifying which zone has been restored.
If Tamper Recognition (see page 24) is disabled, the
console will not report the occurrence of any tampers, wire
faults or tamper restores.
System Trouble Report Codes
Section [149] to [151]
Whenever the system generates one of the instances listed
below, the console can send the appropriate report code to
the central station identifying the type of system trouble.
Section [149]
Console Tamper: A tamper has been detected on the
console itself (see Console Tamper Supervision on page
33).
AC Failure: Magellan has detected a loss of AC power.
Transmission of this report code can be delayed (see
Power Failure Report Delay on page 31).
Battery Failure: The backup battery is disconnected or
battery voltage is ≤ (less than or equal to)6.9V.
Timer Loss: The console has detected a loss in time or
clock failure.
Section [150]
Future use
Fail To Communicate: The Magellan console has failed
all attempts to communicate with the central station. The
report code will be transmitted upon the next successful
attempt.
Wireless Low Battery: The battery voltage of an Omnia
wireless transmitter (motion detector or contact switch)
has dropped below recommended limits.
Tx Supervision Loss: Check-in Supervision (page 24)
has been enabled and a transmitter is no longer
communicating with the system.
Section [151]
Future use
Future use
Future use
Future use
System Trouble Restore Codes
Sections [152] to [154]
Whenever the system restores one of the troubles listed in
sections [149] and [150] (see System Trouble Report Codes
on page 27), the Magellan console can send the appropriate
report code to the central station identifying the type of
system trouble restored. If Telephone Line Monitoring is
enabled (see page 30), use the first two digits to program a
TLM Restore report code that the console can transmit.
Special Reporting Codes
Sections [155] and [156]
Whenever the system generates one of the instances listed
below, the Magellan console can send the appropriate
report code to the central station identifying the type of
system occurrence.
Section [155]
Cold Start: The console was completely shutdown (no
battery, no AC) and then was restarted.
Test Report: A test report has been generated
automatically (see page 31).
Future use
WinLoad Logout: The console has ended
communication with WinLoad.
Section [156]
Installer logon: Installer has entered the programming
mode.
Installer Logout: Installer has exited the programming
mode.
Closing Delinquency: The last time the system was
armed is greater than the programmed Closing
Delinquency timer (page 23).
Future use
Console Telephone Numbers
Magellan can dial up to two different central station telephone
numbers and one Pager telephone number. You can enter any
digit from 0 to 9 and any special keys or functions (see Table 9
on page 28) up to a maximum of 32 digits. If the number is less
than 32 digits, press the left [
ACTION] key (ok) to save the
message.