18 Reference & Installation Manual
Intellizone Delay Timer
Section [065]: 010 to 255 seconds; Default = 48 seconds
Enter the desired 3-digit value into section [065] to
program the Intellizone Delay Timer.
Delay Before Alarm Report Code Transmission
Sections [001] to [016]: Zones 1 to 16; option [7]
Option [7] OFF = Delay alarm transmission disabled
(default)
Option [7] ON = Delay alarm transmission enabled
This feature is commonly used with Entry Delay zones to
reduce false alarms created by new users who may not
disarm the system in time. This feature works as follows:
When an alarm condition occurs on a zone with this
option enabled, the console enables the bell/siren
output, but does not report the alarm to the central
station until the end of the Alarm Before Transmission
Delay.
During this period, disarming the system disables the
bell/siren output and cancels the report code
transmission.
Alarm Transmission Delay
Section [075]: 001 to 255 seconds; 000 = Disabled;
Default = 0 seconds
Enter the desired 3-digit delay value into section [075] to
program the Alarm Transmission Delay.
Force Zones
Sections [001] to [016]: Zones 1 to 16; Option [8]
Option [8] OFF = Force zone disabled
Option [8] ON = Selected zone is Force enabled (default)
Any open Force zones at the time of arming will be
considered deactivated by the console. If during this period
a deactivated zone is closed, the console will revert that
zone to active status. Consequently, the console will
generate an alarm if the zone is breached.
Fire zones cannot be programmed with the Force Zone
option because the console will not bypass a Fire zone
when the system is being Force armed.
Zones 15 and 16 become Hardwire Zones
Section [095]: Options [1] and [2]
Option [1] OFF = Wireless zone 15 remains unchanged (default)
Option [1] ON = Wireless zone 15 uses the on-board hardwire
zone input 1
Option [2] OFF = Wireless zone 16 remains unchanged (default)
Option [2] ON = Wireless zone 16 uses the on-board hardwire
zone input 2
The Magellan console comes with two on-board zone inputs,
hardwire zone inputs 1 and 2. Section [095] options [1] and [2]
allow you to convert zones 15 and 16 from wireless to hardwire
by allowing you to connect hardwire detection devices (i.e. door
contact) to zone inputs 1 and 2.
With section [095] option [1] ON, zone 15 is connected to
zone input 1.
With section [095] option [2] ON, zone 16 is connected to
zone input 2.
EOL (End-Of-Line) Zones
Section [095]: Option [3]
Option [3] OFF = Hardwire zones 1 & 2 do not require EOL
resistors (default)
Option [3] ON = Hardwire zones 1 & 2 require EOL resistors
This feature only applies to Magellan’s on-board zone
inputs. Section [095] options [1] and/or [2] (see Zones 15
and 16 become Hardwire Zones on page 18) must be ON in
order to use this feature.
If the hardwire detection devices connected to Magellan’s zone
inputs 1 and 2 have input terminals that require 1K9 end of line
resistors, enable (ON) section [095] option [3]. For details on
using EOL resistors, refer to page 10.