Magellan MG-6130 Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Systemy kontroli dostępu bezpieczeństwa Magellan MG-6130. Magellan MG-6130 Installation manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
All-In-One Wireless Security System V2.0
Model #: MG-6130 / MG-6160
Reference and Installation Manual
We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit
www.paradox.com and send us your comments.
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - Model #: MG-6130 / MG-6160

All-In-One Wireless Security System V2.0Model #: MG-6130 / MG-6160Reference and Installation ManualWe hope this product performs to your complete sati

Strona 2

8 Reference & Installation ManualFigure 4: Auxiliary Output ConnectionTelephone Line ConnectionsThe Magellan console can be connected to a teleph

Strona 3 - Table of Contents

Paradox Magellan Systems 9Normally Closed (N.C.) as detailed in PGM Normal State (Onboard Only) on page 35.If the current draw on the PGMs is to exc

Strona 4

10 Reference & Installation ManualWinLoad ConnectionThe Magellan console can be programmed and monitored through the WinLoad Installer Upload/Dow

Strona 5 - Introduction

Paradox Magellan Systems 11apply power to the console. For more information, see Programming Using a Paradox Memory Key on page 13.Figure 13: Connec

Strona 6 - Quick Setup

12 Reference & Installation Manual4. Slide the Magellan’s open slots labeled D (see Figure 16 on page 11) onto the wall plate’s tabs labeled B (s

Strona 7 - Deleting Zones

Paradox Magellan Systems 13Programming MethodsWinLoad Installer Upload/Download SoftwareProgram the Magellan console remotely or on-site using the W

Strona 8 - Deleting Outputs

14 Reference & Installation ManualUser CodesA person must be assigned to a User code in order to have access to Magellan. A User code defines the

Strona 9 - Installation

Paradox Magellan Systems 15Zone ProgrammingMagellan supports up to 32 wireless zones whereby each zone can be configured with a different zone defin

Strona 10 - Programmable Outputs (PGMs)

16 Reference & Installation ManualFollow/Stay ZonesSections [001] to [032]: Zones 1 to 32, 3-digit # = 004Follow/Stay zones function as follows:•

Strona 11 - Hardwire Zone Connections

Paradox Magellan Systems 1724Hr. Gas ZonesSections [001] to [032]: Zones 1 to 32, 3-digit # = 012When a 24Hr. Gas zone opens, whether it is armed or

Strona 13 - Location and Mounting

18 Reference & Installation Manual• During the Intellizone Delay, a second zone has caused an alarm.• During the Intellizone Delay, the zone in a

Strona 14 - Tabletop Mounting

Paradox Magellan Systems 19Assigning Wireless Zone TransmittersSections [201] to [232]: Zones 1-32; Wireless Transmitters 1-32Sections [201] to [232

Strona 15 - Programming Methods

20 Reference & Installation ManualThe signal strength can also be verified by performing a system test. See Quick Setup on page 4 for more inform

Strona 16 - User Codes

Paradox Magellan Systems 21 The button of the MG-REM1 and MG-REM2 remote controls has been permanently programmed to disarm the system. However, w

Strona 17 - Zone Programming

22 Reference & Installation ManualArming and DisarmingRegular Arming Switches to Stay ArmingSection [092]: Option [4]Option [4] OFF = Regular arm

Strona 18

Paradox Magellan Systems 23Auto-Arming OptionsSection [092]: Option [3]Option [3] OFF = Auto-arm system using Regular arm (default)Option [3] ON = A

Strona 19 - Zone Options

24 Reference & Installation ManualAlarm OptionsBell Cut-off TimerSection [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 minutesAfter an a

Strona 20 - EOL (End-Of-Line) Zones

Paradox Magellan Systems 25Table 5: Tamper Recognition OptionsTamper Bypass OptionsSection [094]: Option [5]Option [5] OFF = Ignore any tampers dete

Strona 21 - Strength

26 Reference & Installation ManualWhen the Magellan system is in entry delay, the console will send a message to the MG-2WPGM telling it that it

Strona 22 - Assigning Remote Controls

Paradox Magellan Systems 27Reporting and Dialer SettingsReport CodesA report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 t

Strona 23 - Wireless Repeater Options

Paradox Magellan Systems 1Table of ContentsIntroduction... 3About Magellan and this Manual...

Strona 24 - Arming and Disarming

28 Reference & Installation Manual• Fire Panic: Panic keys [7] and [9] (see page 26) or the appropriate button(s) on a remote control (see page 2

Strona 25 - Paradox Magellan Systems 23

Paradox Magellan Systems 29• Keypad AC Failure: The AC voltage of a keypad has dropped below recommended limits.• Repeater Supervision Loss: The con

Strona 26 - Alarm Options

30 Reference & Installation Manual• The console will repeat the message a programmed amount of times (see Voice Message Repetitions on page 30) i

Strona 27 - Tamper Bypass Options

Paradox Magellan Systems 31UL Note: The installer is required to verify the complete compatibility of the DAC Receiver and formats at least once per

Strona 28 - Panic Alarms

32 Reference & Installation ManualWhen option [6] is enabled, the Magellan console will dial a telephone number even if no dial tone is present a

Strona 29 - Reporting and Dialer Settings

Paradox Magellan Systems 33Power Failure Report DelaySection [070]: 001 to 255 minutes; 000 = Disabled; Default = 15 minutesThe Magellan console wil

Strona 30

34 Reference & Installation ManualProgrammable OutputsA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM

Strona 31 - Console Telephone Numbers

Paradox Magellan Systems 35PGM Normal State (Onboard Only)Section [090]: Options [7] (PGM1) and [8] (PGM2)Option [7] OFF = PGM1 Normally Open (defau

Strona 32 - Reporting Formats

36 Reference & Installation ManualSystem SettingsSoftware ResetSection [199]Performing a software reset will reset all programmed sections back t

Strona 33 - Force Dial Option

Paradox Magellan Systems 37* When a communication failure trouble is acknowledged by pressing [OK], you will be given the option to call your servic

Strona 34 - TLM Fail Timer

2 Reference & Installation ManualWireless PGM Activation Event... 35Wireless PGM Deactivation Event...

Strona 35 - RF Jamming Supervision

38 Reference & Installation ManualWinLoad Software SettingsPanel Answer OptionsThe following two options define how Magellan answers an incoming

Strona 36 - Programmable Outputs

Paradox Magellan Systems 39Appendix 1: Automatic Report Code ListSystem Event Default Contact ID Report Codewhen using sections [790] to [795]Defaul

Strona 37 - SUB-GROUP #]

40 Reference & Installation ManualAC Failure 1 3A1 - AC loss AT - AC TroubleBattery Failure 1 3A9 - Battery test failure YT - System Battery Trou

Strona 38 - System Settings

Paradox Magellan Systems 41Appendix 2: Ademco Contact ID Report Code ListCID# Reporting Code Programming ValueMedical Alarms - 100100 Medical alarm

Strona 39 - HRS] key

42 Reference & Installation ManualCID# Reporting Code Programming Value335 Local printer paper out 54336 Local printer failure 55337 Expansion mo

Strona 40 - WinLoad Software Settings

Paradox Magellan Systems 43CID# Reporting Code Programming Value525 Reversing relay disabled AE526 Notification appliance chk. #3 disabled AF527 Not

Strona 41

44 Reference & Installation ManualIndexNumerics001 to 016 ...15–18021 to 036 ...

Strona 42

Paradox Magellan Systems 45AAC failure report code ...33AC power ...

Strona 43

46 Reference & Installation ManualDeleting ...6Deleting wireless zones

Strona 44

Paradox Magellan Systems 47Normal state ...35Onboard PGM delay ...

Strona 45

Paradox Magellan Systems 3IntroductionAbout Magellan and this ManualMagellan is designed for fast and easy installation. Simply remove it from the bo

Strona 46 - Numerics

48 Reference & Installation ManualTimersAlarm Transmission ...18Auto-arm ...

Strona 47 - Paradox Magellan Systems 45

Paradox Magellan Systems 49WARRANTYParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmansh

Strona 48

paradox.comPrinted in Canada - 01/2007 MAGELLAN-EI07For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m.

Strona 49 - Paradox Magellan Systems 47

4 Reference & Installation ManualQuick SetupFollow these steps to quickly set up Magellan with the required settings for a basic security install

Strona 50

Paradox Magellan Systems 5WARNING! When testing the hardware, the speaker and sirens will also be tested. Avoid close proximity to the Magellan cons

Strona 51 - UL WARNINGS

6 Reference & Installation ManualAdding Outputs1. From the “Output Profile” menu, press [OK].2. Select which output you wish to add, modify or de

Strona 52

Paradox Magellan Systems 7InstallationAC PowerMagellan requires a 12Vac (1A) or 16.5Vac (1A) transformer (not included) to supply power to the conso

Komentarze do niniejszej Instrukcji

Brak uwag