MG5000 43
11.7 Confidential Mode
Section [701] Options [3], [4] and [5]
Option [3] OFF = Confidential Mode Disabled (default)
Option [3] ON = Confidential Mode Enabled
Option [4] OFF = Keypads activate when an access code is entered (default)
Option [4] ON = Keypads activate when a key is pressed
Option [5] OFF = Confidential Mode Timer is 2 minutes (default)
Option [5] ON = Confidential Mode Timer is 5 seconds
If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the Confidential Mode
Timer, all the keypad’s LEDs will be off until either a key is pressed or an access code is entered. When the system exits
Confidential Mode, the keypads will display the system’s status. Confidential Mode is activated by enabling option [3]. Option [4]
regulates whether the keypads will be activated at the touch of a key or only when an access code is entered. Option [5]
determines the amount of time without action before the system enters Confidential Mode (5 seconds or 2 minutes).
11.8 Installer Function Keys
To access the Installer Function keys, press:
[
ENTER]+[INSTALLER CODE]+[MEM] = Test Report: Send the “Test Report” report code programmed in section [875] to the
monitoring station.
[
ENTER]+[INSTALLER CODE]+[STAY] = Cancel Communication: Cancels all communication with the WinLoad software or with the
monitoring station until the next reportable event.
[
ENTER]+[INSTALLER CODE]+[SLEEP] = Answer WinLoad Software: Will force the console to answer an incoming call from the
monitoring station that is using the WinLoad software.
[
ENTER]+[INSTALLER CODE]+[BYP] = Call WinLoad Software: Will dial the PC telephone number programmed in section [915] in
order to initiate communication with a computer using the WinLoad software.
[ENTER]+[INSTALLER CODE]+[TBL] = Installer Test Mode: The installer test mode will allow you to perform walk tests where the
siren will squawk to indicate opened zones. Press the [
TBL] key again to exit.
11.9 Daylight Savings Time
Section [730]: General Zone Options 2
Option [1] OFF = Daylight Savings Time Disabled (default)
Option [1] ON = Daylight Savings Time Enabled
With section [730] option [1] ON, Magellan adjusts the system’s clock (time) for daylight savings changes. At 2:00AM on the first
Sunday of a full weekend in April, the console will add one hour to the programmed time (clock). At 2:00 AM on the last Sunday
of a full weekend in October, the console will subtract one hour from the programmed time (clock). By default, when section [730]
is set at 00, the time is set for the US, Canada etc. For other countries see Daylight Savings Programming in the MG5000
Programming Guide and set the country code in section [731].
11.10 Audible Trouble Warning Except AC Failure
Section [700]: General System Options
Option [3] OFF = Audible trouble warning except AC failure
Option [3] ON = Audible trouble warning except AC failure (default)
When this option is enabled the panel will generate an audible trouble warning on all troubles except AC failure.
11.11 Audible Trouble Warning on AC Failure
Section [700]: General System Options
Option [4] OFF = Audible trouble warning on AC failure (default)
Option [4] ON = Audible trouble warning on AC failure
When this option is enabled the panel will generate an audible trouble warning in the event of an AC failure.