5.1.3 Entry Delay 1 / Stay / Sleep Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 03
Upon regular arming, the zone is Entry Delay 1 (see Entry Delay 1 Zones on page 14). Upon Stay/Sleep arming, the
zone is bypassed by the system. See Table 4 on page 17 for any exceptions.
5.1.4 Entry Delay 2 / Stay / Sleep Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 04
Upon regular arming, the zone is Entry Delay 2 (see Entry Delay 2 Zones on page 14). Upon Stay/Sleep arming, the
zone is bypassed by the system. See Table 4 on page 17 for any exceptions.
5.1.5 Follow Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 05
When a Regular, Stay, or Sleep armed Follow Zone opens, the control panel will immediately generate an alarm,
unless an entry delay zone opens first:
• If a Regular/Stay/Sleep armed Follow Zone opens after an entry delay zone opens, the control panel waits until the
entry delay timer has elapsed before generating an alarm.
• If a Regular/Stay/Sleep armed Follow Zone opens after more than one entry delay zone opens, the control panel
will wait until the entry delay timer of the zone that opened first has elapsed.
This feature is commonly used when a motion detector is protecting the area occupied by the entry point keypad. This
will prevent the motion detector from causing an alarm when a user enters through the entry point to disarm the
system. See Table 4 on page 17 for any exceptions.
5.1.6 Follow / Stay Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 06
Upon regular arming or sleep arming, the zone is Follow. Upon Stay arming, the zone is bypassed by the system. See
Table 4 on page 17 for any exceptions.
5.1.7 Follow / Stay / Sleep Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 07
Upon regular arming, the zone is Follow (see Follow Zones on page 15). Upon Stay or Sleep arming, the zone is
bypassed by the system. See Table 4 on page 17 for any exceptions.
5.1.8 Instant Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 08
When an armed Instant Zone opens, the control panel immediately generates an alarm. Instant Zones are commonly
used for windows, patio doors, skylights and other perimeter type zones. See Table 4 on page 17 for any exceptions.
5.1.9 Instant / Stay Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 09
All zones defined as Instant/Stay zones become Instant zones when the system is Regular armed. All zones defined
as Instant/Stay zones become bypassed when the system is Stay armed. See Table 4 on page 17 for any exceptions.
5.1.10 Instant / Stay / Sleep Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 10
All zones defined as Instant/Stay/Sleep zones become Instant zones when the system is Regular armed. All zones
defined as Instant/Stay/Sleep zones become bypassed when the system is Stay or Sleep armed. See Table 4 on
page 17 for any exceptions.