12 Programming Guide
System Options
[090] General Options Bold = Default setting
Option OFF ON
[1] Access code length 6 digits 4 digits
[2] Audible trouble warning (except AC power failures) Disabled Enabled
[3] Lock master code Disabled Enabled
[4] Use user code 16 as duress code Disabled Enabled
[5] Console tamper supervision Disabled Enabled
[6] Need code to bypass zones Disabled Enabled
[7] PGM1 normal state N.O. N.C.
[8] PGM2 normal state N.O. N.C.
[091] General Options Bold = Default setting
Option OFF ON
[1] Panic 1 (Emergency) Disabled Enabled
[2] Panic 2 (Auxiliary) Disabled Enabled
[3] Panic 3 (Fire) Disabled Enabled
[4] Panic 1: Silent or audible alarm Silent Audible
[5] Panic 2: Silent or audible alarm Silent Audible
[6] Panic 3: Silent or audible alarm Silent Audible
[7] PGM1 used as Direct output X10 output 7
[8] PGM2 used as Direct output X10 output 8